RSS feed for stoft


stoft 88 research notes and wiki edits



Joined almost 5 years ago

High-Rez WebCam Spectrometers

by stoft over 1 year ago | 8 | 1,560 | 2

Abstract Having experimented with software algorithms to enhance the PLab-3 spectrometer d...

Read more


PLab-3 Proto Slit Upgrade

by stoft over 1 year ago | 5 | 592 | 2

Abstract The [PLab-3 Upgrade Proto](https://publiclab.org/notes/stoft/03-02-2015/plab-3-sp...

Read more


All Paper-n-Tape Mock-Up Upgrade of PLab 3 Spectrometer

by stoft over 1 year ago | 0 | 515 | 2

Abstract From discussion with @abdul of PLab Kits, it appears there is an opportunity for ...

Read more


Stability upgrade mockup for PLab Spectrometer 3.0

by stoft over 1 year ago | 13 | 1,394 | 8

Abstract The [PLab 3.0 Spectrometer](https://publiclab.org/wiki/desktop-spectrometry-kit-3...

Read more



Spectrometer DVD-Alignment Auto-Correction

by stoft almost 2 years ago | 0 | 1,008 | 0

Abstract This is a continuation of my investigation into extracting stable data from the P...

Read more


Spectrometer Peak-Hold

by stoft almost 2 years ago | 0 | 775 | 0

Abstract This is a brief follow-on to my previous note on spectrometer noise reduction via...

Read more


Spectrometer Noise Solution?

by stoft almost 2 years ago | 4 | 1,385 | 1

Abstract This is a continuation of my series on spectrometer noise which now focuses on ob...

Read more


Spectrometer Time Filter

by stoft almost 2 years ago | 0 | 744 | 0

Abstract This next 'chapter' in the stability series attempts to observe the potential for...

Read more



Spectrometer Noise

by stoft almost 2 years ago | 5 | 1,193 | 1

Abstract This is a follow-on to my discussion of [Spectrometer Stability](https://publicla...

Read more


Spectrometer Stability

by stoft almost 2 years ago | 9 | 857 | 3

Abstract Continuing the effort to define the specification limits of my [Prototype PLab V3...

Read more


405nm LED vs Laser

by stoft almost 2 years ago | 19 | 2,370 | 1

Abstract 405nm Lasers provide a powerful, narrow-band, pin-point source of monochromatic U...

Read more


CFL Selection

by stoft about 2 years ago | 3 | 1,470 | 3

Introduction Wavelength calibration of a PLab spectrometer requires a stable light source ...

Read more



OTK Proto3 Analysis

by stoft about 2 years ago | 5 | 1,429 | 2

Preface In my previous Research Note 'OTK Proto3' ( https://publiclab.org/notes/stoft/01-1...

Read more


OTK Proto3

by stoft about 2 years ago | 6 | 1,840 | 7

Preface I received an early Beta OTK to assemble and test but found the mechanics of the d...

Read more


Musings: Spectrometer Stability

by stoft over 2 years ago | 11 | 1,934 | 2

My experiments with the PLab 3.0 spectrometer and PLab oil-test kit prototypes demonstrated the r...

Read more


PLab 3 Gain Correction

by stoft almost 3 years ago | 37 | 3,585 | 5

In a previous note ( http://publiclab.org/notes/stoft/02-25-2015/plab-spectrometer-gain-correcti...

Read more



PLab 3 Spectrometer Upgrade Prototype

by stoft almost 3 years ago | 11 | 4,419 | 4

Abstract Even though the ink is barely dry on the new manuals for the PLab 3.0 Spectromete...

Read more


CFL Cal Error Explained

by stoft almost 3 years ago | 3 | 1,770 | 2

The PLab spectrometer can be, and should be, calibrated for wavelength. Presently this can be acc...

Read more


Optimal Slit Width

by stoft almost 3 years ago | 0 | 3,169 | 2

The PLab spectrometers use a thin slit to provide pseudo-collimated light which has been effectiv...

Read more


PLab 3 Sanm Camera Focus

by stoft almost 3 years ago | 0 | 2,109 | 2

There has been continuing discussion about PLab spectrometer camera focus since poor focus can ad...

Read more



PLab Spectrometer Gain-Correction

by stoft almost 3 years ago | 25 | 2,960 | 4

Calibrating the PLab spectrometer for absolute intensity will likely remain a difficult and expen...

Read more


PLab's WebCam (Non)Linearity

by stoft almost 4 years ago | 0 | 3,610 | 3

We all know that when looking at the spectrometer's color band, and the associated spectral respo...

Read more


HDR2: Using Over-Exposure to Your Advantage

by stoft almost 4 years ago | 3 | 3,066 | 1

Background Since writing some notes, a while back, on improving dynamic range ( [HDR: In sea...

Read more


HDR: In search of High-er Dynamic Range

by stoft over 4 years ago | 1 | 4,114 | 3

Abstract By adapting the DSLR photography concept of HDR to the webcam spectr...

Read more



Can you get color temperature from spectra

miramon asked about 21 days ago

Answers by stoft

How to interpret the results?

Accepted

amir129 asked about 30 days ago

Answers by stoft

answered on Jan 23, 2018 1

answered on Jan 23, 2018 1

answered on Jan 23, 2018 1

answered on Jan 23, 2018 1

answered on Jan 29, 2018 0

Show all 6 answers »

What mechanical specs can and should PLab spectrometers meet?

stoft asked about over 1 year ago

Answers by stoft

answered on Sep 15, 2016 0

answered on Sep 16, 2016 0

answered on Sep 16, 2016 1

answered on Sep 20, 2016 0

answered on Sep 20, 2016 0

answered on Oct 01, 2016 0

Show all 11 answers »

Question: What does the vertical scale mean?

someHerrings asked about over 2 years ago

Answers by stoft

View these maps at MapKnitter.org »

Title Creation date Image

stoft was awarded the Basic Barnstar by warren for their work published in PLab Spectrometer Gain-Correction.


stoft was awarded the Basic Barnstar by warren for their work published in PLab 3 Gain Correction.


stoft was awarded the Basic Barnstar by liz for their work published in PLab 3 Spectrometer Upgrade Prototype.


stoft was awarded the Basic Barnstar by dhaffnersr for their work published in Optimal Slit Width.


stoft was awarded the Empiricism Barnstar by warren for their work published in PLab 3 Sanm Camera Focus.


stoft was awarded the Empiricism Barnstar by warren for their work published in OTK Proto3 Analysis.


stoft was awarded the Empiricism Barnstar by warren for their work published in Spectrometer Noise.


stoft was awarded the Empiricism Barnstar by Matej for their work published in OTK Proto3.


stoft was awarded the Photo Documentation Barnstar by dhaffnersr for their work published in OTK Proto3.


stoft was awarded the Photo Documentation Barnstar by dhaffnersr for their work published in CFL Selection.